Pace Analytical Services, LLC - Altoona, PA
Altoona, PA · Homeowner samples: yes (lab’s website)
Old list: check before you rely on it
This list is from PA DEP's bulk drinking-water reports printed June 11, 2024 (chemistry and microbiology; the microbiology file is named 06-13-2024). PA DEP's own private-well water-testing page still links these two June 2024 reports (checked Nov 14, 2026); its live lab search did not respond to us on Oct 29 or Nov 14, 2026. Labs may have been added, dropped or changed since then.
At a glance
- What it is certified to test
- 5 of the 9 common well tests on the PA list (see which)
- Price
- no per-test price printed on the lab’s website when we read it (14 Nov 2026): ask for a quote
- Turnaround
- not stated on the state list or the lab’s website: ask when you order
- Homeowner samples
- yes (lab’s own website, read 14 Nov 2026)
Lab facts
- Listed by
- Pennsylvania (Pennsylvania DEP - Laboratory Accreditation Program)
- Address
- 2019 Ninth Avenue, Altoona, PA 16602 · Open in Google Maps
- Phone
- (814) 946-4306
- Website
- www.pacelabs.com/company/lab-results/altoona-laboratoryNot on the state list: found and checked by us, 14 Nov 2026
- Public / homeowner samples
- Homeowner samples: yes (lab’s website)PA DEP accreditation report has no homeowner-sample flag
Certification record
- Certificate ID
- PA DEP 07-00062
- Issued by
- Pennsylvania DEP - Laboratory Accreditation Program (certification program)
- List version
- PA DEP Accredited Labs Report - Drinking Water (chemistry + microbiology), version STALE - report dated 6/11/2024
- We fetched it
- 29 Oct 2026 (file SHA-256 415f95aac8bd…) · open the state file
Tests on the state list
| Contaminant | On this state list | Same lab, other state lists |
|---|---|---|
| Coliform / E. coli | Named on the official list | Maryland, Virginia, West Virginia |
| Nitrate | Named on the official list | Maryland, Virginia, West Virginia |
| Arsenic | Not named on this list | Maryland |
| Lead | Named on the official list | Maryland, Virginia, West Virginia |
| PFAS | Not named on this list | |
| Uranium | Not named on this list | |
| Radon (water) | Not named on this list | |
| Manganese | Named on the official list | Virginia |
| VOCs | Named on the official list | Maryland, Virginia, West Virginia |
| Other metals | Named on the official list | Maryland, Virginia, West Virginia |
Groups as written on the state list (155)
- 1,1,1,2-Tetrachloroethane
- 1,1,1-Trichloroethane
- 1,1,2,2-Tetrachloroethane
- 1,1,2-Trichloroethane
- 1,1-Dichloro-2-propanone (1,1-Dichloropropanone)
- 1,1-Dichloroethane
- 1,1-Dichloroethene (1,1-Dichloroethylene)
- 1,1-Dichloropropene
- 1,2,3-Trichlorobenzene
- 1,2,3-Trichloropropane (1,2,3-TCP)
- 1,2,4-Trichlorobenzene
- 1,2,4-Trimethylbenzene
- 1,2-Dibromoethane (EDB, Ethylene dibromide)
- 1,2-Dichlorobenzene (o-Dichlorobenzene)
- 1,2-Dichloroethane
- 1,2-Dichloropropane
- 1,3,5-Trimethylbenzene
- 1,3-Dichlorobenzene (m-Dichlorobenzene)
- 1,3-Dichloropropane
- 1,4-Dichlorobenzene (p-Dichlorobenzene)
- 1-Chlorobutane
- 2,2-Dichloropropane
- 2-Butanone (Methyl ethyl ketone, MEK)
- 2-Chlorotoluene
- 2-Hexanone
- 2-Nitropropane
- 4-Chlorotoluene
- 4-Methyl-2-pentanone (MIBK)
- Acetone
- Acrylonitrile
- Alkalinity as CaCO3
- Allyl chloride (3-Chloropropene)
- Aluminum
- Amenable cyanide
- Antimony
- Barium
- Benzene
- Beryllium
- Boron
- Bromate
- … and 115 more
- Named on the official list The state list names this analyte (or a column for it) for this lab.
- Group-level certification Certified for a parent group (e.g. 'Inorganics') that includes this analyte. Confirm the specific test with the lab.
- Partial group certification The list marks the group as 'Partial'. Confirm this analyte with the lab.
- Subcontracted The lab sends this analyte to another accredited lab (MDH 'X*').
STALE LIST: PA DEP bulk Accredited Labs Report(s) dated 6/11/2024. The live PA DEP lab search was unreachable on 2026-10-29 (HTTP 500 / TLS error). Confirm current accreditation with PA DEP or the lab.
Also certified by other states
Same business (same street address and ZIP) on another state's official list. Each state certifies separately, so each listing keeps its own source.
- Virginia · VA lab 460212 / EPA PA01737 · Coliform / E. coli, Nitrate, Lead, Manganese, VOCs, Other metals · Homeowner samples: yes (lab’s website)Virginia DCLS - Drinking Water Certified Labs (analyte detail) (Current as of 8/1/2026)
- Maryland · 275 · Coliform / E. coli, Nitrate, Arsenic, Lead, VOCs, Other metals · Homeowner samples: yes (lab’s website)Maryland's Certified Drinking Water Laboratories (MDE Laboratory Certification Program) (Latest Revisions: 10/1/2026)
- West Virginia · 9963 CM · Coliform / E. coli, Nitrate, Lead, VOCs, Other metals · Homeowner samples: yes (lab’s website)WV OLS Environmental Drinking Water Laboratory Certification Program - Laboratory Certified Parameter List (printed Thursday, August 20, 2026)
Homeowner service and turnaround (lab’s own website)
- Takes homeowner samples: yes. The lab’s site says: “Pace is a certified drinking water testing laboratory serving public water systems, municipalities, private well owners, bottled water producers and environmental consultants.” source
- Prices: no price printed on the lab’s website when we read it on 14 Nov 2026: ask for a quote.
From the lab’s own website, read 14 Nov 2026 and re-read by a second checker; next check due by 12 Feb 2027. Certification fields come from the state list only.
Nearest labs that take homeowner samples
No other lab that takes homeowner samples is within 25 miles of this lab; the nearest is 35 miles away. Distances are straight-line from the address on the state list (approx. = ZIP-code centre). “Takes homeowner samples” comes from a state list column or the lab’s own website, as named.
| Lab and tests named on its list | Town | Distance | Tests in common with this lab | Price printed | Turnaround printed | Homeowner samples: source |
|---|---|---|---|---|---|---|
| Agricultural Analytical Services Laboratory Coliform / E. coli, Nitrate, Arsenic, Lead | University Park, PA | 35 mi (approx.) | 4 | from $15 | In general, tests are complete within... | lab’s own website, read 14 Nov 2026 |
| Pace Analytical Services, LLC - Dubois Coliform / E. coli | Dubois, PA | 46 mi (approx.) | 1 | – | – | lab’s own website, read 14 Nov 2026 |
| Pace Analytical Services LLC - Greensburg PA not broken down on its list | Greensburg, PA | 60 mi | 0 | – | – | Washington list |
| CWM Environmental Coliform / E. coli, Nitrate, Arsenic, Lead | Kittanning, PA | 64 mi | 5 | – | Metiri is committed to a 10-day turna... | lab’s own website, read 14 Nov 2026 |
| White Oak Laboratory LLC Coliform / E. coli, Nitrate | Ridgway, PA | 64 mi (approx.) | 2 | – | – | lab’s own website, read 14 Nov 2026 |
Price and turnaround as printed on each lab’s own website and checked by a second reader; – = not published or not read yet.
Around this lab: Blair County, PA
- Private wells: about 39,117 people, 31% of Blair County’s 125,593 residents (USGS, 2015); rank 31 of 67 counties in Pennsylvania by people on wells.
- EPA radon zone (indoor air): Zone 1: highest potential (average indoor radon may be greater than 4 pCi/L). EPA says the zone map should not decide whether one home needs testing.
- Arsenic above 10 µg/L (USGS model): about 1,116 private-well users (95% range 557 to 2,194; 2010 base), rank 21 of 67 in the state. A screening estimate, not a measurement of any well.
- Older homes (Census ACS 2020–2024): 75% of 55,901 housing units were built before 1980, above the state share of 67%. Homes built before 1986 are more likely to have lead solder or fittings, so test tap water for lead there.
- PFAS in public water nearby (public supply, not your well): 3 public systems serving this county reported EPA UCMR 5 results; 0 had a PFOA or PFOS sample at or above 4.0 ng/L.
County figures describe where the lab is, not the lab. Sources: USGS 2015 water use and 2017 arsenic estimates, EPA radon zones, Census ACS table B25034 (2020–2024), EPA UCMR 5 (2023–2026); details and links on the sources page.
Before you send a sample
Call the lab to confirm it's currently certified for the exact test and method, that it accepts samples from homeowners, and how to collect and ship them. Bacteria samples have short holding times. Status can change between list updates. To check a status, contact the Pennsylvania certification program.
Is this your lab?
Labs can ask for corrections through the agency that publishes their state list. Homeowner service, prices and turnaround above come only from the lab’s own website. To ask us to correct or remove this listing, write to us (how we handle listings).
PA DEP Accredited Labs Report - Drinking Water (chemistry + microbiology). Fetched 2026-10-29 (UTC). File SHA-256 415f95aac8bd…