What does my well water test result mean?

Type in the results from your lab report, as many as it has, and check them all at once against federal limits and, if you pick your state, your state’s own values. Federal limits are written for public water systems, not private wells, but they are the usual yardstick. Nothing you type leaves your browser.

ContaminantResult as printedUnit on your report
More contaminants (13)
ContaminantResult as printedUnit on your report

Fill in only the lines your report has. "ND" or "<" means the lab did not detect it above its reporting limit: type it as printed (for example <5.0) and the checker shows whether that reporting limit is low enough to compare. For bacteria type + (positive / present) or - (negative / absent).

The limits this checker uses

Primary limits (MCLs) protect health and are enforced for public water systems. Secondary standards cover taste, color and staining and are not enforced. A health advisory is EPA guidance, not a rule. None of them is legally binding on a private well.

ContaminantBenchmarkSource
NitrateEPA limit (MCL): 10 mg/L[1] [6]
NitriteEPA limit (MCL): 1 mg/L[1]
ArsenicEPA limit (MCL): 10 µg/L[1]
LeadAction level from Nov 1, 2027: 10 µg/L; Action level today: 15 µg/L[1]
CopperEPA secondary standard (taste, staining): 1 mg/L; EPA action level: 1.3 mg/L[1] [2]
UraniumEPA limit (MCL): 30 µg/L[1]
Gross alphaEPA limit (MCL): 15 pCi/L[1]
Radium 226 + 228 (combined)EPA limit (MCL): 5 pCi/L[1]
Radon in waterProposed limit (1999, never final): 300 pCi/L; Proposed alternative limit (never final): 4000 pCi/L[5]
ManganeseEPA secondary standard (staining, taste): 50 µg/L; EPA lifetime health advisory: 0.3 mg/L[2] [3]
PFOA (a PFAS)EPA limit (MCL, 2024 rule): 4 ng/L[4] [1]
PFOS (a PFAS)EPA limit (MCL, 2024 rule): 4 ng/L[4] [1]
BenzeneEPA limit (MCL): 5 µg/L[1]
Trichloroethylene (TCE)EPA limit (MCL): 5 µg/L[1]
Tetrachloroethylene (PCE)EPA limit (MCL): 5 µg/L[1]
Vinyl chlorideEPA limit (MCL): 2 µg/L[1]
FluorideEPA secondary standard (tooth discoloration): 2 mg/L; EPA limit (MCL): 4 mg/L[1] [2]
BariumEPA limit (MCL): 2 mg/L[1]
IronEPA secondary standard (rusty color, staining): 0.3 mg/L[2]
Total dissolved solids (TDS)EPA secondary standard: 500 mg/L[2]
ChlorideEPA secondary standard (salty taste): 250 mg/L[2]
SulfateEPA secondary standard (salty taste): 250 mg/L[2]
pHEPA secondary range, low end: 6.5; EPA secondary range, high end: 8.5[2]
Total coliform bacteriaAny positive result (health goal: zero)[1]
E. coliAny positive result (health goal: zero)[1]

State values that differ from the federal ones

Some states set their own, lower values or apply health-based values to private wells. Each is listed in the state’s own words, with what it applies to; checked 14 Nov 2026.

StateContaminantValueApplies toSource
CaliforniaBenzeneCalifornia MCL: 1 µg/Lpublic water systemssource
CaliforniaFluorideCalifornia MCL: 2 mg/Lpublic water systemssource
CaliforniaVinyl chlorideCalifornia MCL: 0.5 µg/Lpublic water systemssource
MichiganLeadMichigan lead action level: 12 µg/Lcommunity and nontransient noncommunity water supplies (90th percentile of tap samples)source
MinnesotaBenzeneMinnesota Health Risk Limit (HRL): 2 µg/Lgroundwater that is used for drinking water (guidance; MDH: public water systems are not required to meet HBVs)source
MinnesotaManganeseMinnesota Health Risk Limit (HRL), short-term: 0.1 mg/Lgroundwater that is used for drinking water (guidance; MDH: public water systems are not required to meet HBVs)source
MinnesotaTetrachloroethylene (PCE)Minnesota Health Risk Limit (HRL), cancer: 4 µg/Lgroundwater that is used for drinking water (guidance; MDH: public water systems are not required to meet HBVs)source
MinnesotaPFOA (a PFAS)Minnesota Health Risk Limit (HRL), cancer: 0.0079 ng/Lgroundwater that is used for drinking water (guidance; MDH: public water systems are not required to meet HBVs)source
MinnesotaPFOS (a PFAS)Minnesota Health Risk Limit (HRL): 2.3 ng/Lgroundwater that is used for drinking water (guidance; MDH: public water systems are not required to meet HBVs)source
MinnesotaTrichloroethylene (TCE)Minnesota Health Risk Limit (HRL): 0.4 µg/Lgroundwater that is used for drinking water (guidance; MDH: public water systems are not required to meet HBVs)source
MinnesotaVinyl chlorideMinnesota Health Risk Limit (HRL), cancer: 0.2 µg/Lgroundwater that is used for drinking water (guidance; MDH: public water systems are not required to meet HBVs)source
New HampshireArsenicNew Hampshire MCL: 5 µg/Lpublic water systemssource
New JerseyArsenicNew Jersey MCL: 5 µg/Lpublic water systems (NJ Department of Health tells private well owners to act on results above federal and state public drinking water standards)source
New JerseyBenzeneNew Jersey MCL: 1 µg/Lpublic water systems (NJ Department of Health tells private well owners to act on results above federal and state public drinking water standards)source
New JerseyTetrachloroethylene (PCE)New Jersey MCL: 1 µg/Lpublic water systems (NJ Department of Health tells private well owners to act on results above federal and state public drinking water standards)source
New JerseyPFOA (a PFAS)New Jersey MCL: 14 ng/Lpublic water systems (NJ Department of Health tells private well owners to act on results above federal and state public drinking water standards)source
New JerseyPFOS (a PFAS)New Jersey MCL: 13 ng/Lpublic water systems (NJ Department of Health tells private well owners to act on results above federal and state public drinking water standards)source
New JerseyTrichloroethylene (TCE)New Jersey MCL: 1 µg/Lpublic water systems (NJ Department of Health tells private well owners to act on results above federal and state public drinking water standards)source
New YorkPFOA (a PFAS)New York State MCL: 10 ng/Lpublic water systemssource
New YorkPFOS (a PFAS)New York State MCL: 10 ng/Lpublic water systemssource
PennsylvaniaPFOA (a PFAS)Pennsylvania MCL: 14 ng/Lpublic water systemssource
PennsylvaniaPFOS (a PFAS)Pennsylvania MCL: 18 ng/Lpublic water systemssource
VermontTetrachloroethylene (PCE)Vermont action level (VAL): 1 µg/Lprivate drinking water (wells and springs); Health Department guideline, not an enforceable standardsource
VermontTrichloroethylene (TCE)Vermont action level (VAL): 0.5 µg/Lprivate drinking water (wells and springs); Health Department guideline, not an enforceable standardsource
WisconsinLeadWisconsin DHS action recommendation (laboratory detection level): 0.3 µg/Ldrinking water, including private wells (DHS recommendation)source
WisconsinTrichloroethylene (TCE)Wisconsin DHS recommendation for private wells (take action at 0.5 µg/L or more; proposed groundwater standard not adopted): 0.5 µg/Lprivate well watersource
Re-test with a certified labConfirm a high result

A second sample from a state-certified lab tells you whether the first one was right.

Open the finder →
Not tested yet?Which tests do I need?

Tick what applies to your home and get the tests EPA and CDC recommend.

Open the checklist →