ALLIANCE TECHNICAL GROUP LLC - GREENVILLE

Greenville, SC · Public samples: ask the lab

At a glance

What it is certified to test
6 of the 9 common well tests on the SC list (see which)
Price
not published on the state list: ask the lab for a quote
Turnaround
not stated on the state list or the lab’s website: ask when you order
Homeowner samples
not stated: ask the lab

Lab facts

Listed by
South Carolina (South Carolina Department of Environmental Services (SCDES) - Bureau of Regional Laboratory Services, Office of Environmental Laboratory Certification)
Address
426 FAIRFOREST WAY, Greenville, SC 29607 · Open in Google Maps
Phone
(864) 232-1556
Public / homeowner samples
Public samples: ask the lab
Not stated per lab. SCDES's well-testing page tells well owners: "For Volatile Organic Chemicals, Herbicides, Pesticides, Other Synthetic Organic Parameters, please contact a Commercial Laboratory." It names no lab, and CELMAPP does not say which labs take samples from homeowners.
Left blank on the list
The South Carolina list (version no date printed; CELMAPP data last refreshed 2026-10-10 (LastRefreshDate of SCDES's details table)) gives no website for this lab.

Certification record

Certificate ID
23105001
Issued by
South Carolina Department of Environmental Services (SCDES) - Bureau of Regional Laboratory Services, Office of Environmental Laboratory Certification (certification program)
List version
SCDES Commercial Environmental Laboratory Mapping (CELMAPP) - certified commercial laboratories, Safe Drinking Water, version no date printed; CELMAPP data last refreshed 2026-10-10 (LastRefreshDate of SCDES's details table)
We fetched it
3 Nov 2026 (file SHA-256 3c5b868223a8…) · open the state file

Tests on the state list

6 of the 9 well-water tests we track are named for this lab on the South Carolina list (version no date printed; CELMAPP data last refreshed 2026-10-10 (LastRefreshDate of SCDES's details table)).
ContaminantOn this state listSame lab, other state lists
Coliform / E. coliNamed on the official list
NitrateNamed on the official listNorth Carolina
ArsenicNamed on the official listNorth Carolina
LeadNamed on the official listNorth Carolina
PFASNot named on this list
UraniumNot named on this list
Radon (water)Not named on this list
ManganeseNamed on the official listNorth Carolina
VOCsNamed on the official listNorth Carolina
Other metalsNamed on the official listNorth Carolina
Groups as written on the state list (104)
  • Disinfection By-Products: BROMIDE (EPA 300.0 (1993) - ION CHROMATOGRAPHY)
  • Inorganic - Demand: TOTAL AND DISSOLVED ORGANIC CARBON (SM 5310 B-2022 - HIGH TEMPERATURE COMBUSTION (TOC))
  • Inorganic - Mineral: ALKALINITY (SM 2320 B-2021 - TITRIMETRIC)
  • Inorganic - Mineral: CALCIUM - HARDNESS (CACO3) (SM 3500-CA B-2020- TITRIMETRIC (EDTA))
  • Inorganic - Mineral: CHLORIDE (EPA 300.0 (1993) - ION CHROMATOGRAPHY)
  • Inorganic - Mineral: FLUORIDE (EPA 300.0 (1993) - ION CHROMATOGRAPHY)
  • Inorganic - Mineral: HYDROGEN-ION CONC. (PH) (SM 4500-H B-2021 - ELECTROMETRIC MEASUREMENT)
  • Inorganic - Mineral: SPECIFIC CONDUCTANCE (SM 2510 B-2021 - CONDUCTANCE AT 25 DEGREES C)
  • Inorganic - Mineral: SULFATE (EPA 300.0 (1993) - ION CHROMATOGRAPHY)
  • Inorganic - Miscellaneous: COLOR (SM 2120 B-2021 - VISUAL - PLATINUM COBALT)
  • Inorganic - Miscellaneous: CYANIDE, TOTAL (SM 4500-CN C-2021 - MANUAL DISTILLATION; SM 4500-CN E-2021 - SPECTROPHOTOMETRIC (MANUAL))
  • Inorganic - Miscellaneous: RESIDUAL CHLORINE (SM 4500-CL G-2021 - DPD COLORIMETRIC METHOD)
  • Inorganic - Miscellaneous: SURFACTANTS (MBAS) (SM 5540 C-2021 - COLORIMETRIC (METHYLENE BLUE))
  • Inorganic - Miscellaneous: TEMPERATURE (SM 2550 B-2021 - THERMOMETRIC)
  • Inorganic - Miscellaneous: TURBIDITY (EPA 180.1 (1993) - NEPHELOMETRIC)
  • Inorganic - Nutrient: NITRATE-NITROGEN (EPA 300.0 (1993) - ION CHROMATOGRAPHY; SM 4500-NO3 D-2019 - ION SELECTIVE ELECTRODE)
  • Inorganic - Nutrient: NITRITE-NITROGEN (EPA 300.0 (1993) - ION CHROMATOGRAPHY; SM 4500-NO2 B-2021 - SPECTROPHOTOMETRIC (MANUAL))
  • Inorganic - Nutrient: ORTHOPHOSPHATE (SM 4500-P E-2021 - ASCORBIC ACID (MANUAL SINGLE REAGENT))
  • Inorganic - Nutrient: PHOSPHORUS (SM 4500-P B(5)-2021 - DIGESTION; SM 4500-P E-2021 - ASCORBIC ACID (MANUAL SINGLE REAGENT))
  • Inorganic - Trace Metal: ALUMINUM (EPA 200.7 (1994) - ICP/AES; EPA 200.8 (1994) - ICP/MS)
  • Inorganic - Trace Metal: ANTIMONY (EPA 200.8 (1994) - ICP/MS)
  • Inorganic - Trace Metal: ARSENIC (EPA 200.8 (1994) - ICP/MS)
  • Inorganic - Trace Metal: BARIUM (EPA 200.7 (1994) - ICP/AES; EPA 200.8 (1994) - ICP/MS)
  • Inorganic - Trace Metal: BERYLLIUM (EPA 200.7 (1994) - ICP/AES; EPA 200.8 (1994) - ICP/MS)
  • Inorganic - Trace Metal: CADMIUM (EPA 200.7 (1994) - ICP/AES; EPA 200.8 (1994) - ICP/MS)
  • Inorganic - Trace Metal: CALCIUM (EPA 200.7 (1994) - ICP/AES)
  • Inorganic - Trace Metal: CHROMIUM (EPA 200.7 (1994) - ICP/AES; EPA 200.8 (1994) - ICP/MS)
  • Inorganic - Trace Metal: COPPER (EPA 200.7 (1994) - ICP/AES; EPA 200.8 (1994) - ICP/MS)
  • Inorganic - Trace Metal: IRON (EPA 200.7 (1994) - ICP/AES)
  • Inorganic - Trace Metal: LEAD (EPA 200.8 (1994) - ICP/MS)
  • Inorganic - Trace Metal: MAGNESIUM (EPA 200.7 (1994) - ICP/AES)
  • Inorganic - Trace Metal: MANGANESE (EPA 200.7 (1994) - ICP/AES; EPA 200.8 (1994) - ICP/MS)
  • Inorganic - Trace Metal: MERCURY (EPA 245.1 (1994) - COLD VAPOR (MANUAL))
  • Inorganic - Trace Metal: NICKEL (EPA 200.7 (1994) - ICP/AES; EPA 200.8 (1994) - ICP/MS)
  • Inorganic - Trace Metal: SELENIUM (EPA 200.8 (1994) - ICP/MS)
  • Inorganic - Trace Metal: SILICA, TOTAL (EPA 200.7 (1994) - ICP/AES)
  • Inorganic - Trace Metal: SILVER (EPA 200.7 (1994) - ICP/AES; EPA 200.8 (1994) - ICP/MS)
  • Inorganic - Trace Metal: SODIUM (EPA 200.7 (1994) - ICP/AES)
  • Inorganic - Trace Metal: THALLIUM (EPA 200.8 (1994) - ICP/MS)
  • Inorganic - Trace Metal: ZINC (EPA 200.7 (1994) - ICP/AES; EPA 200.8 (1994) - ICP/MS)
  • … and 64 more
  • Named on the official list The state list names this analyte (or a column for it) for this lab.
  • Group-level certification Certified for a parent group (e.g. 'Inorganics') that includes this analyte. Confirm the specific test with the lab.
  • Partial group certification The list marks the group as 'Partial'. Confirm this analyte with the lab.
  • Subcontracted The lab sends this analyte to another accredited lab (MDH 'X*').

SCDES's CELMAPP lists this lab's Safe Drinking Water certification by parameter and method (SC certification permit 23105001). SCDES publishes no expiry dates and advises: "To request a list of certified labs for specific methods, parameters, and/or analytes, send an email to [email protected] or contact the laboratory directly to verify they have the necessary certification." SCDES marks 1 more Safe Drinking Water parameter/method entry for this lab as (Inactive); they are not shown.

Also certified by other states

Same business (same street address and ZIP) on another state's official list. Each state certifies separately, so each listing keeps its own source.

  • Georgia · GA Lab # 880 · analytes not broken down · Public samples: ask the lab
    Laboratories Certified by Georgia for Chemical Monitoring (January 9, 2025)
  • North Carolina · 45710 · Nitrate, Arsenic, Lead, Manganese, VOCs, Other metals · Public samples: ask the lab
    NC SLPH Environmental Sciences - Certified Drinking Water Laboratories (Commercial) (generated on request (no date printed), fetched 2026-11-07)

Before you send a sample

Call the lab to confirm it's currently certified for the exact test and method, that it accepts samples from homeowners, and how to collect and ship them. Bacteria samples have short holding times. Status can change between list updates. To check a status, contact the South Carolina certification program.

Is this your lab?

Labs can ask for corrections through the agency that publishes their state list. Homeowner service, prices and turnaround above come only from the lab’s own website. To ask us to correct or remove this listing, write to us (how we handle listings).

Certified as ofno date printed; CELMAPP data last refreshed 2026-10-10 (LastRefreshDate of SCDES's details table)

SCDES Commercial Environmental Laboratory Mapping (CELMAPP) - certified commercial laboratories, Safe Drinking Water. Fetched 2026-11-03 (UTC). File SHA-256 3c5b868223a8…

Open the state lab-certification page (official list)