Home / Texas / Lab

Edwards Aquifer Research and Data Center

San Marcos, TX · Homeowner samples: yes (lab’s website)

At a glance

What it is certified to test
1 of the 9 common well tests on the TX list (see which)
Price
from $25 (Coliform, Total/E. coli Colilert Present/Absent), as printed on the lab’s website, read 14 Nov 2026
Turnaround
not stated on the state list or the lab’s website: ask when you order
Homeowner samples
yes (lab’s own website, read 14 Nov 2026)

Lab facts

Listed by
Texas (Texas Commission on Environmental Quality (TCEQ) - Laboratory Accreditation Program (NELAP))
Address
220 East Sessoms Drive, San Marcos, TX 78666-4616 · Open in Google Maps
Phone
(512) 245-2329
Website
www.eardc.txst.edu
Not on the state list: found and checked by us, 14 Nov 2026
Public / homeowner samples
Homeowner samples: yes (lab’s website)
Not stated in the list.

Certification record

Certificate ID
TX Lab ID T104704402
Issued by
Texas Commission on Environmental Quality (TCEQ) - Laboratory Accreditation Program (NELAP) (certification program)
Expiry on the list
8/31/2027 · expires in 289 days
List version
TCEQ Laboratory Approval Status - List of Accredited Laboratories (public database, Matrix: Drinking Water), version Live database, searched 2026-11-15 ("accurate as of the date and time of the search")
We fetched it
15 Nov 2026 (file SHA-256 d09853d6717d…) · open the state file

Tests on the state list

1 of the 9 well-water tests we track are named for this lab on the Texas list (version Live database, searched 2026-11-15 ("accurate as of the date and time of the search")).
ContaminantOn this state list
Coliform / E. coliNamed on the official list
NitrateNot named on this list
ArsenicNot named on this list
LeadNot named on this list
PFASNot named on this list
UraniumNot named on this list
Radon (water)Not named on this list
ManganeseNot named on this list
VOCsNot named on this list
Groups as written on the state list (7)
  • Chloride
  • Fluoride
  • Nitrite as N
  • Residue-filterable (TDS)
  • Sulfate
  • Total coliforms and E. coli (P/A)
  • Total hardness as CaCO3
  • Named on the official list The state list names this analyte (or a column for it) for this lab.
  • Group-level certification Certified for a parent group (e.g. 'Inorganics') that includes this analyte. Confirm the specific test with the lab.
  • Partial group certification The list marks the group as 'Partial'. Confirm this analyte with the lab.
  • Subcontracted The lab sends this analyte to another accredited lab (MDH 'X*').

TCEQ lists 7 drinking-water analytes this lab is accredited for. TCEQ database: lab type University; 'Commercial?' Yes; 'Is Primary?' Yes. Phone from TCEQ's PWS Laboratory Map Table (Last Updated 03/26/2026).

Homeowner service and turnaround (lab’s own website)

  • Takes homeowner samples: yes. The lab’s site says: “EARDC also offers NELAP-accredited water testing services, providing accurate, professional analysis for individuals, organizations, and municipalities.” source
  • Who collects: You collect the sample with the lab's bottles. source

From the lab’s own website, read 14 Nov 2026 and re-read by a second checker; next check due by 12 Feb 2027. Certification fields come from the state list only.

Prices the lab prints, compared

TestPrice as printed by the lab
Coliform, Total/E. coli Colilert Present/Absent
Total coliform / E. coli, SM9223
Coliform, Total/E. coli Colilert Present/Absent ... $25.00 source
Nitrogen, Nitrates
Nitrate, EPA 353.2
Nitrogen, Nitrates EPA 353.2 Rev. 2.0 48 hours 125 mL Cool to <=6C $35.00 source
Well Study
pH, TDS, Total Alkalinity, Total Hardness, Ca, Mg, Fe, Pb, Mn, K, Na, Sulfate, Chloride, Fluoride, Nitrate + Nitrite as N, Total Coliform (Absence/Presence)
Well Study pH, Total Dissolved Solids(TDS), Total Alkalinity, Total Hardness ... Total Coliform (Absence/Presence) $300.00 source
  • Bacteria (coliform / E. coli) against other Texas labs: median $25 across 6 other labs that print a price on their own site; 3 of them charge less than $25.
  • Nitrate against other Texas labs: median $30 across 3 other labs that print a price on their own site; 2 of them charge less than $35.

Comparison uses the lowest single-test price this lab prints; panels and ranges are left out. For comparison only, not a quote.

Nearest labs that take homeowner samples

1 other certified lab that takes homeowner samples is within 25 miles of this lab. Distances are straight-line from the address on the state list (approx. = ZIP-code centre). “Takes homeowner samples” comes from a state list column or the lab’s own website, as named.

Lab and tests named on its listTownDistanceTests in common with this labPrice printedTurnaround printedHomeowner samples: source
Guadalupe-Blanco River Authority Regional Laboratory
Coliform / E. coli, Nitrate
Seguin, TX22 mi1from $30–lab’s own website, read 14 Nov 2026
Lower Colorado River Authority - Environmental Laboratory Services
Coliform / E. coli, Nitrate, Arsenic, Lead, PFAS
Austin, TX26 mi1from $46Normal Turnaround (7-14 Business Days)lab’s own website, read 14 Nov 2026
Texas Department of State Health Services Laboratory - Austin
Coliform / E. coli, Nitrate, Arsenic, Lead
Austin, TX32 mi1from $18.39–lab’s own website, read 14 Nov 2026
Integrity Testing, Inc.
Nitrate, Arsenic, Lead
Austin, TX35 mi0from $350Our standard turnaround time is usual...lab’s own website, read 14 Nov 2026
ALS Group USA, Corp
not broken down on its list
Houston, TX144 mi0––Washington list

Price and turnaround as printed on each lab’s own website and checked by a second reader; – = not published or not read yet.

Around this lab: Hays County, TX

  • Private wells: about 15,786 people, 8% of Hays County’s 194,739 residents (USGS, 2015); rank 19 of 254 counties in Texas by people on wells.
  • EPA radon zone (indoor air): Zone 3: low potential (average indoor radon may be less than 2 pCi/L). EPA says the zone map should not decide whether one home needs testing.
  • Arsenic above 10 µg/L (USGS model): about 339 private-well users (95% range 258 to 448; 2010 base), rank 50 of 254 in the state. A screening estimate, not a measurement of any well.
  • Older homes (Census ACS 2020–2024): 12% of 104,675 housing units were built before 1980, below the state share of 33%. Homes built before 1986 are more likely to have lead solder or fittings, so test tap water for lead there.
  • PFAS in public water nearby (public supply, not your well): 16 public systems serving this county reported EPA UCMR 5 results; 1 had a PFOA or PFOS sample at or above 4.0 ng/L.

County figures describe where the lab is, not the lab. Sources: USGS 2015 water use and 2017 arsenic estimates, EPA radon zones, Census ACS table B25034 (2020–2024), EPA UCMR 5 (2023–2026); details and links on the sources page.

Before you send a sample

Call the lab to confirm it's currently certified for the exact test and method, that it accepts samples from homeowners, and how to collect and ship them. Bacteria samples have short holding times. Status can change between list updates. To check a status, contact the Texas certification program.

Is this your lab?

Labs can ask for corrections through the agency that publishes their state list. Homeowner service, prices and turnaround above come only from the lab’s own website. To ask us to correct or remove this listing, write to us (how we handle listings).

Certified as ofLive database, searched 2026-11-15 ("accurate as of the date and time of the search")

TCEQ Laboratory Approval Status - List of Accredited Laboratories (public database, Matrix: Drinking Water). Fetched 2026-11-15 (UTC). File SHA-256 d09853d6717d…

Open the state lab-certification page (official list)